{"product_id":"80kva-3phase-ups-415v-hipulse-u-6pulse-250a-battery-breaker","title":"Vertiv Liebert Hipulse- U 80KVA (3:3)415V,6 Pulse ,online UPS","description":"\u003ch3\u003e🔷\u003cspan\u003e \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(157, 77, 77); text-decoration: underline;\"\u003eVLAUE PERPOSITION\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003e80 kVA 3 Phase Online UPS (3:3 configuration) from the HiPulse-U series\u003c\/strong\u003e\u003c\/span\u003e is a robust and high-performance power backup solution designed for critical applications such as data centers, IT infrastructure, industrial automation, healthcare facilities, and commercial establishments. Engineered with advanced double-conversion technology, this UPS ensures uninterrupted, clean, and stable power supply to sensitive equipment.\u003c\/p\u003e\n\u003ch3\u003e🔷\u003cspan style=\"text-decoration: underline; color: rgb(157, 67, 67);\"\u003eKERY FEATURES\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAEIBxAA\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eReliability\u003c\/span\u003e  \u003c\/strong\u003e: Features a fully digital architecture with twin DSP (Digital Signal Processing) control for precise power management.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAEIBxAB\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\"\u003eLoad Handling\u003c\/strong\u003e\u003c\/span\u003e: \u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCapable of handling 100% non-linear and 100% unbalanced loads without derating.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAEIBxAC\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOverload Capacity\u003c\/span\u003e \u003c\/strong\u003e: \u003cspan style=\"color: rgb(0, 0, 0);\"\u003eDesigned to support 110% load for 60 minutes and up to 150% load for 1 minute.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAEIBxAA\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eScalability\u003c\/span\u003e \u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/span\u003e While this is a single module, it is compatible with 1 + N or N +1 configurations, allowing up to 6 units to be paralleled for future growth.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAEIBxAA\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan\u003e\u003cstrong data-start=\"1426\" data-end=\"1472\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIntegrated 250 Amp Battery Circuit Breaker\u003c\/span\u003e :  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003eProvides enhanced safety and protection for battery banks, ensuring secure operation and easy maintenance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e🔷 \u003cspan style=\"text-decoration: underline; color: rgb(135, 54, 54);\"\u003eAPPLICATION\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"2rtlpr\" data-start=\"3187\" data-end=\"3218\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eData Centers \u0026amp; Server Rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"82b9re\" data-start=\"3219\" data-end=\"3253\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIT \u0026amp; Networking Infrastructure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1lt0aiu\" data-start=\"3254\" data-end=\"3287\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIndustrial Automation Systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"14bp950\" data-start=\"3288\" data-end=\"3324\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eHospitals \u0026amp; Diagnostic Equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"8zeydi\" data-start=\"3325\" data-end=\"3361\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eBanking \u0026amp; Financial Institutions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1koqeos\" data-start=\"3362\" data-end=\"3389\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eTelecom \u0026amp; Control Rooms. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e🔷\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(147, 67, 67); text-decoration: underline;\"\u003e WHY CHOOSE THIS UPS ? \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong data-start=\"3431\" data-end=\"3455\"\u003e80 kVA HiPulse-U UPS\u003c\/strong\u003e is designed to deliver maximum uptime, superior power quality, and long-term reliability. Its rugged construction, intelligent controls, and safety features make it an ideal choice for businesses that cannot afford power interruptions.\u003c\/p\u003e\n\u003ch3\u003e🔷 \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(146, 69, 69); text-decoration: underline;\"\u003eTECHNICAL SPECIFICATION\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003ePARAMENTER \u003c\/th\u003e\n\u003cth style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003eSPECIFCATION \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e80 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eInput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e3 Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eOutput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e3 Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRectifier Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e6 Pulse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eTechnology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eOnline Double Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eBattery Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e250 Amp (External\/Internal Option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e415V AC (3 Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eUp to 94%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eForced Air Cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003eOverload, Short Circuit, Battery Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003eLCD \/ LED Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.6475%; height: 19.5938px; text-align: center;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"width: 55.9915%; height: 19.5938px; text-align: center;\"\u003eData Centers, IT Systems, Industry, Healthcare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SLV India Infotech","offers":[{"title":"Default Title","offer_id":46787516072111,"sku":"Vertiv Liebert Hipulse- U 80KVA (3:3)415V,6 Pulse ,online UPS","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0689\/5563\/5887\/files\/images_14.jpg?v=1776757038","url":"https:\/\/www.slvindia.com\/en-ae\/products\/80kva-3phase-ups-415v-hipulse-u-6pulse-250a-battery-breaker","provider":"SLV India Infotech","version":"1.0","type":"link"}